6-22 ES45 Owner's Guide
6.6.5 Configuring Dial-Out Alert
When you are not monitoring the system from a modem connection,
you can use the RMC dial-out alert feature to remain informed of sys-
tem status. If dial-out alert is enabled, and the RMC detects alarm
conditions within the managed system, it can call a preset pager num-
ber.
You must configure remote dial-in for the dial-out feature to be enabled. See
Section 6.6.4.
To set up the dial-out alert feature, enter the RMC from the local serial termi-
nal or local VGA monitor.
Example 6–2 Dial-Out Alert Configuration
RMC> set dial
Dial String: ATXDT9,15085553333
RMC> set alert
Alert String: ,,,,,,5085553332#;
RMC> enable alert
RMC> clear alert
RMC> send alert
Alert detected!
RMC> clear alert
RMC> status
.
.
Alert Enable: Enabled
.
.
A typical alert situation might be as follows:
The RMC detects an alarm condition, such as over temperature warning.
The RMC dials your pager and sends a message identifying the system.
You dial the system from a remote serial terminal.
You enter the RMC, check system status with the env command, and, if the
situation requires, power down the managed system.
When the problem is resolved, you power up and reboot the system.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq AlphaServer ES45 1B and is the answer not in the manual?

Compaq AlphaServer ES45 1B Specifications

General IconGeneral
BrandCompaq
ModelAlphaServer ES45 1B
CategoryServer
LanguageEnglish

Related product manuals