Troubleshooting 7-7
7.2 RMC Error Messages
Table 7–2 lists the error messages that might be displayed on the
operator control panel by the remote management console during
power-up. Most fatal error messages prevent the system from
completing its power-up. Contact your service provider if a fatal error
is displayed. Warning messages require prompt attention but may not
prevent the system from completing its power-up.
The VTERM and CTERM regulators referenced in the table are located on the
system motherboard.
Table 7–2 RMC Error Messages
Message Meaning
AC loss No AC power to the system.
CPUn failed CPU failed. “n” is 0, 1, 2, or 3.
VTERM failed No VTERM voltage to CPUs.
CTERM failed No CTERM voltage to CPUs.
Fan5, 6 failed Main fan (6) and redundant fan (5) failed.
OverTemp failure System temperature has passed the high threshold.
No CPU in slot 0 Configuration requires that a CPU be installed in slot 0.
CPU door opened System card cage cover off. Reinstall cover.
TIG error
Code essential to system operation is not loaded and/or
running or TIG flash is corrupt.
Mixed CPU types
Different types of CPU are installed. Configuration
requires that all CPUs be the same type.
Bad CPU ROM data Invalid data in EEROM on the CPU.
2.5V bulk failed 2.5V regulator failed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq AlphaServer ES45 1B and is the answer not in the manual?

Compaq AlphaServer ES45 1B Specifications

General IconGeneral
BrandCompaq
ModelAlphaServer ES45 1B
CategoryServer
LanguageEnglish

Related product manuals