Troubleshooting 7-9
7.3 SROM Error Messages
The SROM power-up identifies errors that may or may not prevent the
system from coming up to the console. It is possible that these errors
may prevent the system from successfully booting the operating
system. Errors encountered during SROM power-up are displayed on
the operator control panel (OCP). Some errors are also displayed on
the console terminal if the console output is set to serial.
Table 7–3 lists the SROM error messages. Contact your service provider.
Table 7–3 SROM Error Messages
Code SROM Message OCP Message
FD PCI data path error PCI Err
FA No usable memory detected No Mem
EF Bcache data lines test error BC Error
EE Bcache data march test error BC Error
ED Bcache address test error BC Error
EC CPU parity detection error CPU Err
EB CPU ECC detection error CPU Err
EA Bcache ECC data lines test error BC Error
E9 Bcache ECC data march test error BC Error
E8 Bcache TAG lines test error BC Error
E7 Bcache TAG march test error BC Error
E6 Console ROM checksum error ROM Err
E5 Floppy driver error Flpy Err
E4 No real-time clock (TOY) TOY Err
E3 Memory data path error Mem Err
Continued on next page

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq AlphaServer ES45 1B and is the answer not in the manual?

Compaq AlphaServer ES45 1B Specifications

General IconGeneral
BrandCompaq
ModelAlphaServer ES45 1B
CategoryServer
LanguageEnglish

Related product manuals