6.9 Troubleshooting Tips
Table 6–3 lists possible causes and suggested solutions for symptoms
you might see.
Table 6–3 RMC Troubleshooting
Symptom Possible Cause Suggested Solution
You cannot enter the
RMC from the modem.
The RMC may be in
soft bypass or firm by-
pass mode.
Issue the show
com1_mode command
from SRM and change the
setting if necessary. If in
soft bypass mode, you can
disconnect the modem ses-
sion and reconnect it.
The terminal cannot
communicate with the
RMC correctly.
System and terminal
baud rates do not
match.
Set the baud rate for the
terminal to be the same as
for the system. For first-
time setup, suspect the
console terminal, since the
RMC and system default
baud is 9600.
RMC will not answer
when the modem is
called.
Modem cables may be
incorrectly installed.
Check modem phone lines
and connections.
RMC remote access is
disabled or the modem
was power cycled since
last being initialized.
From the local serial ter-
minal or VGA monitor, en-
ter the set password and
set init commands, and
then enter the enable re-
mote command.
The modem is not con-
figured correctly.
Modify the modem initiali-
zation string according to
your modem documenta-
tion.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq AlphaServer ES45 1B and is the answer not in the manual?

Compaq AlphaServer ES45 1B Specifications

General IconGeneral
BrandCompaq
ModelAlphaServer ES45 1B
CategoryServer
LanguageEnglish

Related product manuals