Booting and Installing an Operating System 3-3
3.1.1 auto_action
The SRM auto_action environment variable determines the default ac-
tion the system takes when the system is power cycled, reset, or ex-
periences a failure.
Systems can boot automatically (if set to autoboot) from the default boot device
under the following conditions:
• When you first turn on system power
• When you power cycle or reset the system
• When system power comes on after a power failure
• After a bugcheck (OpenVMS)orpanic(Tru64 UNIX or Linux)
The factory setting for auto_action is halt.Thehalt setting causes the system
to stop in the SRM console. You must then boot the operating system manually.
For maximum system availability, auto_action can be set to boot or restart.
• With the boot setting, the operating system boots automatically after the
SRM init command is issued or the Reset button is pressed.
• With the restart setting, the operating system boots automatically after the
SRM init command is issued or the Reset button is pressed, and it also re-
boots after an operating system crash.
Example
To set the default action to boot, enter the following SRM commands:
P00>>> set auto_action boot
P00>>> init

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq AlphaServer ES45 1B and is the answer not in the manual?

Compaq AlphaServer ES45 1B Specifications

General IconGeneral
BrandCompaq
ModelAlphaServer ES45 1B
CategoryServer
LanguageEnglish

Related product manuals