CRS-300 1:10 Redundancy Switch MN/CRS300.IOM
Front Panel Operation Revision 19
6–17
The code indicates the parameter within the MGC configuration string that is causing the
Redundant Modem to refuse it.
The three-letter instruction code is indicated also to assist decoding the following problem
parameters:
► For the CDM-570/A or CDM-570L/AL modem, the code is the decimal number indicating
the fault parameter within its MGC configuration code:
External Reference setting
EDMAC Slave Address range
Statistics Sample Interval
► For the CDM-Qx/QxL modem, the code is the decimal number indicating the fault
parameter within its MGC configuration code:
00 NO ERROR 01 ITF Interface
02 LBO T1 Line Build-Out 03 FRM Framing mode
04 TFQ Tx Frequency 05 TFT Tx FEC Type
06 TMD Tx Modulation 07 TCR Tx FEC Code Rate
08 TDR Tx Data Rate 09 TSI Tx Spectrum Invert
10 TSC Tx Scrambler state 11 TPL Tx Power Level
12 TCK Tx Clock 13 TDI Tx Data Invert
14 TXO Tx Carrier State 15 AUP AUPC enable
16 APP AUPC parameters 17 WUD Warm-Up Delay
Tx roll-off (alpha) factor
22 RFQ Rx Frequency 23 RFT Rx FEC Type
26 RDR Rx Data Rate 27 RSI Rx Spectrum Invert
28 RDS Rx Descrambler state 29 RDI Rx Data Invert
30 RSW Rx Sweep Width 31 EBA Eb/No Alarm point
32 BCS Rx Buffer clock source 33 RRS Rx Reed-Solomon
34 RBS Rx Buffer size/enable 35 RCI Rx Data Clock Invert
36 ERF External Reference setting 37 EFM EDMAC Framing mode
38 ESA EDMAC Slave Address range 39 TST Test mode (read-only)
40 MSK Alarm Masks 41 RTS Request-To-Send control
42 SSI Statistics Sample Interval 43 CNM CnC Mode
46 CRA CnC Re-acquisition Time