6 Type code and Selection
6.1 Ordering
F C - P T
130BB836.10
X S A B CX X X X
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 302221 23 272524 26 28 29 31 373635343332 38 39
X D
Figure 6.1 Type Code Example
Congure the right adjustable frequency drive for the right
application from the internet-based drive congurator and
generate the type code string. The drive congurator
automatically generates an 8-digit ordering number for
delivery to the local sales oce.
The drive congurator can also establish a project list with
several products and send it to a Danfoss sales represen-
tative.
Access the drive congurator on the global Internet site:
www.danfoss.com/drives.
6.1.1 Type Code
An example of the type code is:
FC-202PK75T4E20H1BGCXXXSXXXXA0BXCXXXXD0
The meaning of the characters in the string can be found
in Table 6.1 and Table 6.2. In the example above, a
PROFIBUS DP V1 and a 24 V backup option are built-in.
Description Position
Possible choices
1)
Product group 1-2 FC
Drive series 4-6 202: FC 202
Power rating 8-10 0.25–90 kW (0.34–125 hp)
Phases 11 S: Single phase
T: Three phases
AC line
voltage
12 2: 200–240 V
4: 380–480 V
6: 525–600 V
7: 525–690 V
Description Position
Possible choices
1)
Enclosure 13-
15
E20: IP20
E55: IP 55/NEMA Type 12
P20: IP20 (with backplate)
P21: IP21/NEMA Type 1 (with
backplate)
P55: IP55/NEMA Type 12 (with
backplate)
Z20: IP 20
1)
E66: IP 66
RFI lter 16-
17
Hx: No EMC lters built into the
adjustable frequency drive
H1: Integrated EMC lter. Fulll EN
55011 Class A1/B and EN/IEC
61800-3 Category 1/2
H2: No additional EMC lter. Fulll
EN 55011 Class A2 and EN/IEC
61800-3 Category 3
H3: Integrated EMC lter. Fulll EN
55011 class A1/B and EN/IEC
61800-3 Category 1/2
H4: Integrated EMC lter. Fulll EN
55011 class A1 and EN/IEC
61800-3 Category 2
H5: Marine versions. Fulll same
emissions levels as H2 versions
Brake 18 B: Brake chopper included
X: No brake chopper included
T: Safe torque o No brake
1)
U: Safe torque o brake chopper
1)
Display 19 G: Graphical local control panel
(LCP)
N: Numerical local control panel
(LCP)
X: No local control panel
Coating PCB 20 C: Coated PCB
R: Coated PCB + Ruggedized
X: No coated PCB
Type code and Selection Design Guide
MG20N622 Danfoss A/S © 09/2014 All rights reserved. 121
6 6

Table of Contents

Other manuals for Danfoss VLT AQUA Drive FC 202