Table 56. Configuration validation error(continued)
Error Description Possible cause and
recommendations
Example
assembled incorrectly.
Verify element (cable,
risers, etc) placement in
the system.
Config
Missing
iDRAC found a configuration element
missing within the closest match
detected.
Missing or damaged cable,
device, or part
Config Missing: adapter HBA
Missing element or cable
is reported in HWC8010
error logs. Install the
missing element (cable,
risers, etc).
Config Missing : SL cable
PLANAR_SL8 and CTRL_DST_PA1
Comm Error A configuration element is not responding
to iDRAC using the management interface
while running an inventory check.
System management
sideband communication
Comm Error: Backplane 2
Unplug AC Power, reseat
the element and replace
the element if the problem
persists.
Error messages
This section describes the error messages displayed on the screen during POST or captured in the system event log (SEL)/
LifeCycle (LC) log.
Table 57. Error message HWC8010
Error code HWC8010
Message The System Configuration Check operation resulted in the following issue involving the indicated
component type
Arguments Riser, floating card ( adapter PERC like BOSS), backplane, processor, cable, or other components
Detailed Description The issue identified in the message is observed in the System Configuration Check operation.
Recommended
Response Action
Do the following and retry the operation:
1. Disconnect the input power.
2. Check for proper cable connection and component placement. If the issue persists, contact the
service provider.
Category System Health (HWC = Hardware Config)
Severity Critical
Trap/EventID 2329
Table 58. Error message HWC8011
Error code HWC8011
Message The System Configuration Check operation resulted in multiple issues involving the indicated component
type
Arguments Riser, floating card ( adapter PERC like BOSS), backplane, processor, cable, or other components
Detailed Description Multiple issues are observed in the System Configuration Check operation.
Recommended
Response Action
Do the following and retry the operation:
1. Disconnect the input power.
2. Check for proper cable connection and component placement. If the issue persists, contact the
service provider.
Minimum to POST and system management configuration validation 57