AX-Series Motion Controller Instructions Manual Chapter 2
142
To change the periodic mode, Periodic of MC_CamTable will be pulled down and shift to False, while the slave
axis remains its periodicity.
After rebooting MC_CamTable, the slave axis enters non-periodic mode. As soon the last period movement
performed by the slave axis is completed, EndOfProfile will shift to True and remain unchanged.
MC_CamIn
Execute
InSync
Busy
EndOfProfile
Position
Master
Slave
0
0
MC_CamTableSelec
Execute
Periodic
Done
Busy