AX-Series Motion Controller Instructions Manual Chapter 2
287
This instruction enables the group axis DMC_Axis_Group specified by AxisGroup to enter the GroupDisable
state.
DMC_GroupDisable is run when groupdis_exe (bExecute) changes to true. When groupdis_done (bDone)
changes to true, it indicates that DMC_Axis_Group axis group has successfully entered GroupDisable state.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta AX Series and is the answer not in the manual?

Delta AX Series Specifications

General IconGeneral
Input Voltage24 VDC
Expansion ModulesUp to 8 modules
SeriesAX
Operating Temperature0°C to 55°C
CPU32-bit
Communication PortsRS-232, RS-485, Ethernet
TypeProgrammable Logic Controller (PLC)
Programming LanguageLadder Diagram
I/O CapacityUp to 256 I/O points