100
Chapter 4 FAQ
"101F-****" The % milling bur chucking has slipped out.
"%" indicates a milling bur stocker number from 1 to 15.
Situation/Error Cause
The collet may have come loose.
Procedure
A
Hold down the operation button on the built-in panel.
This will clear the error.
B
Retighten the collet.
" P.71 "Retightening the Collet"
Situation/Error Cause 2
The milling conditions may be excessively strict.
Procedure
A
Hold down the operation button on the built-in panel.
This will clear the error.
B
Review the CAM settings and the shape specied in the CAD data.
If the Error Occurs Again
The collet may have worn out and its ability to retain the milling bur may have deteriorated. Replace the collet
with a new one.
" P.62 "Situations Requiring Part Replacement"
"1020/1021-****" The % milling bur is too long./The % milling bur is too short.
"%" indicates a milling bur stocker number from 1 to 15.
Situation/Error Cause
There is a possibility that the position of the milling bur holder is not correct.
Procedure
A
Check the milling bur.
Check that the milling bur length is appropriate (40 to 55 mm).
B
Check the position of the milling bur holder.
" P.45 "Step 3: Setting the Milling Bur"