EasyManua.ls Logo

DGSHAPE DWX-52DCi - 1022-**** the % Milling Bur was Not Found; 1022-0010 the Cleaning Tool was Not Found

DGSHAPE DWX-52DCi
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Responding to Error Messages
101
Chapter 4 FAQ
"1022-****" The % milling bur was not found.
"%" indicates a milling bur stocker number from 1 to 15.
Situation/Error Cause
The milling bur has not been set or it may have been set on an incorrect stocker number.
Procedure
Set the milling bur in the correct position.
If the error occurred during milling
Press the operation button on the built-in panel.
Milling will resume.
If the error occurred while the machine was on standby
Hold down the operation button on the built-in panel.
This will clear the error.
Situation/Error Cause 2
There is a possibility that the ATC magazine is out of position.
Procedure
Perform automatic correction.
" P.65 "Correcting the Milling Machine"
If the Error Occurs Again
The collet may have worn out. Replace the collet. If the error occurs again even after you replace the collet, replace
the spindle unit.
" P.62 "Situations Requiring Part Replacement"
"1022-0010" The cleaning tool was not found.
Situation/Error Cause
The cleaning tool has not been set or it may have been set on an incorrect stocker number.
Procedure
Set the cleaning tool in the correct position.
" P.47 "Step 4: Setting the Cleaning Tool"

Table of Contents