Responding to Error Messages
103
Chapter 4 FAQ
Situation/Error Cause 2
When using CAM to select the stocker number, the stocker number set as the second or third milling bur in
Intelligent Tool Control has been selected.
Procedure
When using CAM to select the stocker number, do not select the stocker number set as
the second or third milling bur in Intelligent Tool Control.
" P.55 "Automatically Switching Out the Worn Milling Bur (Intelligent Tool Control)"
"1029-0000" The spindle experienced an overload.
Situation/Error Cause
• The milling bur is worn.
• A workpiece that cannot be milled by the machine is being used.
• The milling conditions are too strict.
Procedure
A
Turn off the power.
B
Check the milling bur, the workpiece, and the CAM settings as well as the shape specied
in the milling data.
C
Allow the machine to rest for some time before turning on the power.
The motor may have overheated.
"102A-0000" The spindle experienced overcurrent.
Situation/Error Cause
• The milling bur is worn.
• A workpiece that cannot be milled by the machine is being used.
• The milling conditions are too strict.
Procedure
A
Turn off the power.
B
Check the milling bur, the workpiece, and the CAM settings as well as the shape specied
in the milling data.