Responding to Error Messages
109
Chapter 4 FAQ
"104C-0000" All stockers are full, so the adapter could not be returned.
Procedure
Check the adapters that are not in use and remove them from their adapter stockers.
If the error occurred during milling
Press the operation button on the built-in panel.
Milling will resume.
If the error occurred while the machine was on standby
Hold down the operation button on the built-in panel.
This will clear the error.
"104D-00**" An adapter with the same ID was found.
"%" indicates the ID of the adapter (A to Z) or of the automatic correction jig (#).
Procedure
Attach the adapters again so that there are no duplicate adapter IDs.
"104E-****" The % limit switch was not found.
"%" indicates the axis name (L or T).
Situation/Error Cause
A foreign object may be present along the movement path of the disk changer.
Procedure
A
Remove any foreign objects that are present along the movement path of the disk
changer.
B
Restart the machine.
If the Error Occurs Again