22 | Technical data
264 AXH1230‐UK ﴾ENG﴿ ‐ Apollo KM
22.2 Environmental conditions
Although the vehicle can be used in several different situations, however, it is necessary to observe, as a
precautionarymeasure,compliancewithminimumstandardsofoperationasspecifiedbelow:
Parameter Allowed values
Operatingtemperatures from20°Cto+40°C
(from4°Fto104°F)
Averagedailytemperature <+40°C
(<104°F)
Storagetemperature from25°Cto+50°C
(from13°Fto122°F)
Humidity from20%to95%
Altitude <2500m
(<8200ft)
Table1: Environmentalconditionstable
22.3 Electromagnetic Interference
Inthecaseofadditionalequipmentinstalledbythecustomer,theusermustverifyiftheinstallationcauses
interferenceofanykindwiththetoolsofthevehicle;ifso,theusermustcorrectsuchinterferences.
Itisessentialtopayparticularattentiontomobiledevicessuchasradiocommunications(telephones)that
mustbeinstalledbytrainedservicetechniciansmustuseexternallymountedantennas.
Ingeneral,itshouldbekeptinmindthatanyadditionalelectricalequipmentinstalledmustcomplywiththe
EMCDirective2004/108/ECandmustbearthe"CE"mark.
22.4 Radiations
Themachine,inconditionsofnormaluse,doesnotproduceanytypeofradiation,ionizingandnonionizing,
thatcancauseproblemstotheoperator.
22.5 Standard hydraulic oil
Specifications: DIECI Hydro Telehandler Fluid ISO46
ISO 67434 HV, Afnor NFE 48602, ISO 11158, DIN 51524 Part 3 HVLP, Afnor NFE 48603 HV, ASTM D6158,
DenisonHF0/HF1/HF2,EatonVickersI286S/M2950S,CincinnatiMachineP68/P69/P70,AfnorNFE
48690(dry),AfnorNFE48691(wet),U.S.Steel126/127/136,JCMASHK,Boschvariablevanepumps,Rexroth
RE90220,SauerDanfoss520L0463,GeneralMotors(LS2)LH031/LH041/LH061,SEB181222.
Properties Analysis method Unit of measure Value
Densityat15°C ASTMD1298 kg/l 0.88
Kinematicviscosityat40°C ASTMD445 cSt 46.6
Kinematic viscosity at
100°C
ASTMD445 cSt 8.6