Parameter Description
0 Disabled
1 Broadcast notification to network upon joining
Default
0
DO (Miscellaneous Device Options)
A bitfield that contains advanced device options that do not have dedicated AT commands.
Leave unused bits clear so future device options are not inadvertently enabled during a firmware
update.
Bit field:
Bit Description
0 Reserved.
1 Reserved.
2 Reserved.
3 Reserved.
4 Disable Tx packet extended timeout.
5 Disable ACK for end device I/O sampling.
6 Enable High-RAM concentrator.
7
When the Network Watchdog triggers, search for a coordinator on a new network to join. The
Network Watchdog must be enabled for this to take effect (NW(Network Watchdog Timeout) >
0).
With this bit set, the device will remain on the current network until a valid coordinator is
found. If the coordinator is found on a different network, the device will leave the current
network and join the new network. See Network Locator option.
Parameter range
0 - 0xFF
Default
0x40
DC (Joining Device Controls)
A bitfield that contains advanced joining device controls that do not have dedicated AT commands.
These options only apply to joining devices (CE=0).
Leave unused bits clear so future device controls are not inadvertently enabled during a firmware
update.