AT commands Security commands
Digi XBe 3 Zigbe RF Module
186
Parameter Description
0 Encryption Disabled
1 Encryption Enabled
Default
0
EO (Encryption Options)
A bitfield that contains advanced encryption options that do not have dedicated AT commands. These
options are only applicable when encryption is enabled (EE = 1).
Leave unused bits clear so future encryption options are not inadvertently enabled during a firmware
update.
Bit field:
Bit Description
0 Send/receive NWK keys in the clear (unsecure).
1
1 = Centralized Trust Center.
0 = Distributed Trust Center.
2 Use EUI64-hashed link keys (used on centralized trust center only).
3 Emit join notification frames (used on centralized trust center only).
4 Allow joining using well-known default link keys (unsecure).
5 - 15 Reserved.
Parameter range
0 - 0xFF
Default
2
DM (Disable Features)
A bit field mask that you can use to enable or disable specific features.
Bit Description
0
Reserved
1 Reserved