Frame descriptions Remote AT Command Request frame - 0x17
Digi XBe 3 Zigbe RF Module
265
Remote AT Command Request frame - 0x17
Description
Used to query or set device parameters on a remote device. For parameter changes on the remote
device to take effect, you must apply changes, either by setting the Apply Changes options bit, or by
sending an AC command to the remote.
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
format.
Frame
data
fields Offset Description
Frame
type
3 0x17
Frame ID 4
Identifies the data frame for the host to correlate with a subsequent
response.
If set to 0, the device does not send a response.
64-bit
destination
address
5-12
MSB first, LSB last. Set to the 64-bit address of the destination device.
Reserved 64-bit address for the coordinator = 0x0000000000000000
Broadcast = 0x000000000000FFFF.
Reserved broadcast address: 0x000000000000FFFF
Note Digi highly discourages sending remote AT commands to a broadcast.
You will only receive a single acknowledgment despite there being multiple
recipients, and there is no assurance that the broadcast will be successfully
received by the rest of the network.
Reserved 13-14
MSB first, LSB last. Set to match the 16-bit network address of the destination
device, if known. Set to 0xFFFE if the address is unknown, or if sending a
broadcast.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee 3 ZigBee and is the answer not in the manual?

Digi XBee 3 ZigBee Specifications

General IconGeneral
BrandDigi
ModelXBee 3 ZigBee
CategoryControl Unit
LanguageEnglish

Related product manuals