Secure access Secure transmission failures
Digi XBee® 3 Zigbee® RF Module
47
Secure transmission failures
This section describes the error messages you can see when trying to send a secure packet.
Data Frames - 0x10 and 0x11 frames
n Response frame type: Transmit Status frame - 0x8B
Possible error statuses:
Status Description Reason
0x34 No Secure
Session
Connection
The sending node does not have an active session with the destination
node.
0x35 Encryption
Failure
The encryption process failed. Only likely to be seen when using manual
SRP and when an invalid encryption parameter was passed in.
Remote AT Commands- 0x17 frames
n Response frame type: Remote Command Response frame - 0x97
Possible error statuses:
Status Description Reason
0x0B No Secure Session
Connection
The sending node does not have an active session with the
destination node.
0x0C Encryption Error There was an internal encryption error on the radio.
0x0D TO Bit Not Set The client has a session with the server but forgot to set the TO
bit.