AT commands Location commands
Digi XBe 3 Zigbe RF Module
226
Parameter range
0 - 2
Parameter Description
0 1.25 V reference
1 2.5 V reference
2 VDDreference
Default
0
IS (Force Sample)
Immediately forces an I/O sample to be generated. If you issue the command to the local device, the
sample data is sent out the local serial interface. If sent remotely, the sample data is returned as a AT
Command Response frame - 0x88.
If the device receives ERROR as a response to an IS query, there are no valid I/O lines to sample.
Parameter range
N/A
Default
N/A
V+ (Supply Voltage Threshold)
Define the supply voltage threshold that appends the supply voltage to outgoing I/O sample frames.
If the measured supply voltage falls below or equal to this threshold, the supply voltage will be
appended to outgoing I/O sample frames and set bit 7 of the Analog Channel Mask.
Set V+ to 0 to not include the supply voltage.
Set V+ to 1 to always include the supply voltage.
Example
To include a measurement of the supply voltage when it falls below 2.7 V, set V+ to 2700 = 0xA8A.
Parameter range
0 - 0xFFFF (in mV)
Default
0
Location commands
The following commands are user-defined parameters used to store the physical location of the
deployed device.