AT commands Zigbee Addressing commands
Digi XBe 3 Zigbe RF Module
189
Bit Meaning
2 Serial Data
When set to 1, the device will not emit any serial data that was sent insecurely.
This functionality applies to devices that are configured for Transparent mode, but in this
instance, only the SRP server would be AP = 0, the client would still have to send the Secure
Session Control frame - 0x2E via API mode. The server will also not emit any 0x90 or 0x91
frames when this bit is set.
Default
0
Zigbee Addressing commands
The following AT commands are used for communication with a Zigbee network after association.
SH (Serial Number High)
Displays the upper 32 bits of the unique IEEE 64-bit extended address assigned to the XBee in the
factory.
This value is read-only and it never changes.
Parameter range
0x0013A200 - 0x0013A2FF [read-only]
Default
Set in the factory
SL (Serial Number Low)
Displays the lower 32 bits of the unique IEEE 64-bit RF extended address assigned to the XBee in the
factory.
This value is read-only and it never changes.
Parameter range
0x0013A200 - 0x0013A2FF [read-only]
Default
Set in the factory
MY (16-bit Network Address)
Reads the 16-bit network address of the device, which is randomly assigned by the network upon
association.
A value of 0xFFFE means the device has not joined a Zigbee network.
Parameter range
0 - 0xFFFF [read-only]