AT commands Security commands
Digi XBee® 3 Zigbee® RF Module
188
Default
0
KT (Trust Center Link Key Registration Timeout)
When registering a joining device using a 0x24 registration API frame, this parameter determines the
length of time the key table entry persists before expiring.
This timeout is separate from the NJ join time. The join window does not open when a device is
registered to the trust center.
Parameter range
0x1E - 0xFFFF (seconds)
Default
0x12C (500 Seconds)
I? (Install Code)
The install code is a random key assigned to every Zigbee 3.0 device at the factory. This install code
can be used to securely register a device to a trust center using a 0x24 registration frame and option
bit.
For the install code to be used by the joining device, DC bit 0 must be set on the joiner.
Parameter range
0 - 0xFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF [read-only]
Default
Set in the factory.
SA (Secure Access)
The Secure Access Options bit-field defines the feature set(s) intended to be secure against
unauthorized access. The XBee 3 Zigbee RF Module should establish a secure session in order to
access functionality defined by the feature set(s) on the local device.
A password must be set using the Secure Session Salt and Verifier before access is secured.
Parameter range
0 - 0x1F (up to 0xFFFF)
Bit field
Unused bits must be set to 0. These bits may be logically OR'ed together:
Bit Meaning
0 Reserved
1 Remote AT Commands
When set to 1 and if a password has been set, the device will not respond to insecure Remote
AT Command requests (API Frame 0x17) but still can send insecure Remote AT Commands.