EasyManuals Logo

Digi XBee 3 ZigBee User Manual

Digi XBee 3 ZigBee
347 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #266 background imageLoading...
Page #266 background image
Frame descriptions Remote AT Command Request frame - 0x17
Digi XBe 3 Zigbe RF Module
266
Frame
data
fields Offset Description
Remote
command
options
15 Bit Bit mask Description
1 0x02
Apply changes on remote. If not
set, the changes are not applied
until the next command with bit
1 set or until the AC command is
sent.
4 0x10 Send the remote command
securely.
Set all other bits to 0 so that they will not have unexpected effects in case the
other bits are defined later.
AT
command
16-17
Command name: two ASCII characters that identify the command.
Command
parameter
18-n If present, indicates the parameter value you request for a given register. If
no characters are present, it queries the register.
Example
The following example sends a remote command:
In this example, the 64-bit address of the remote device is 0x0013A200 40401122. The destination 16-
bit address is unknown. The BH command is being set to 1 on the remote device with the change
being applied immediately (equivalent to sending a separate AC command).
Frame data fields Offset Example
Start delimiter 0 0x7E
Length MSB 1 0x00
LSB 2 0x10
Frame type
3 0x17
Frame ID 4 0x01