Frame descriptions Secure Session Control frame - 0x2E
Digi XBee® 3 Zigbee® RF Module
280
Frame
data
fields Offset Description
Secure
Session
Options
12 Bitfield of supported options that alter the session behavior.
Bit
Setting Description
0
Client-side control:
0: Login
1: Logout
Clear this bit to log in to a server as a
client.
If this bit is clear, the local device will
act as a client and initiate SRP
authentication with the target
server.
Set this bit to log out of an existing
session as a client.
If this bit is set, the local device will
attempt to end an existing client-side
session with the target server. When
set, all other options and the timeout
field will be ignored. No password
should be provided when this bit is
set.
Note If a password is supplied on a
logout frame, a 0x0A error is given in
the 0xAE response frame and the
session remains connected.
1 Server Termination
Server-side session termination.
If this bit is set, the server will end an
incoming session(s). The address
field can be set to a specific node or
the broadcast address can be used
to end all incoming sessions.
2
Timeout type
0: Fixed
1: Inter-packet
Determines what type of timeout will
be used: Fixed or Inter-packet
For fixed interval timeouts, the
session terminates after the timeout
period has elapsed.
An inter-packet timeout is refreshed
every time a secure transmission
occurs between client and server.