Frame descriptions Secure Session Response frame - 0xAE
Digi XBe 3 Zigbe RF Module
318
Format
The following table provides the contents of the frame. For details on frame structure, see API frame
format.
Frame data
fields Offset Description
Frame type 3 0xAE - Secure Session Response
Response type 4 0x00 - Login response
0x01 - Logout response
64-bit source
Address
5-12 Responding device
Status 13 Typical statuses:
0x00 - SRP operation was successful
0x01 - Invalid Password - SRP verification failed due to mismatched M1
and M2 values
0x02 - Session request was rejected as there are too many active
sessions on the server already
0x03 - Session options or timeout are invalid
0x04 - The requested session does not exist
0x05 - Timed out waiting for the other node to respond
0x06 - Could not allocate memory needed for authentication
0x07 - A request to terminate a session in progress has been made
0x08 - There is no password set on the server
0x09 - There was no initial response from the server
0x0A- Data within the frame is not valid or formatted incorrectly
Statuses that could be observed when performing manual SRP:
0x80 - Server received a packet that was intended for a client or vice
versa
0x81- Received an SRP packet we were not expecting
0x82- Offset for a split value (A/B) came out of order
0x83- Unrecognized or invalid SRP frame type
0x84- Authentication protocol version is not supported
0xFF - An undefined error occurred