G Service Rho 1012/1030
G Service
1 Inspection and cleaning intervals
Warranty and guarantee claims can only be made if the test images
have been retained.
When? What?
Daily
Check housing covers visually.
Check condition of the encoder ruler and have it purged
by Durst service technicians if heavily soiled.
Carry out the work of daily print head maintenance
( Page 130 / Print head maintenance).
Check all warning signs for cleanlines s and re a dability
and replace if necessary.
Ensure that all protective equipment is attached and
in proper working order. This includes th e following
protective equipment (in particular):
Protective switches
Housing covers
Limit sw itches of the stacking unit
–UVlampprotection
UV curtain at media outlet
Wiping printing plate( Page 130 / Print head
maintenance)
On the last workd ay
in c onnection with the
weekly shutdown
Carry out the work of weekly print head maintenance
( Page 130 / Print head maintenance).
Weekly
On the rst workday at
the beginning of shift
Carry out the work of weekly print head maintenance
( Page 130 / Print head maintenance).
Monthly
Check air lter of UV lamps an
d change if necessary
( Page 125 / Checking and rep
lacing air lter).
Clean exhaust grate.
Change lter of the ink separator ( Page 124 / Changing
lter of the ink separator)
118 / 147 2004 2013 © Durst Phototechnik AG www.durst-online.com , Rho 101 2/103 0, Issued 07/20 13