E Operation Rho 1012/1030
Collision of the table with the limiting plates!
Damage to the stacking unit
Test the height of the limiting plates before operation. Tighten the
fixing s c rews only lightly fo r the te st.
Adjust the h eight as follows:
– Loosen the fixing screws ( 1).
– Adjust the limiting plate (2) to the desired height.
– Tighten t he fixing screws only lightly.
– Test the setting in operation.
– Tighten the fixing screws.
9.5 Adjusting the light barrier for vertical tracking
The vertical position of the light barrier c an be adjusted.
1
2
Fig. 36 Adjusting the light barr
ier
1. Loosen the fixing lever (2).
2. Adjust the vertica
l positio n with the adju sting sc re w (1) to the desired
position.
3. Tighten the fixing lever.
10 Loading medium
10.1 Loading a pl
ate medium with an automatic feed
table
Plate m edia can be loaded in the following operating modes:
70 / 1 47 2004 – 2013 © Durst Phototechnik AG – www.durst-online.com , Rho 101 2/103 0, Issued 07/20 13