Rho 1012/1030 G Service
The power of the suction strips will drop off if the seal between
the top and bottom sections is defective. For this reason, the lter
materialmaynotbeclampedinbetweenthesealingringandtop
part at any point.
6. Put on the top part while ensuring that the lter m aterial is n ot clamp ed in
between the sealing ring and top part at any point when doing so.
7. Screw down the top part.
8. Screw on the ink separator.
9. Connect the hoses.
8 Checking and replacing air lter
Energized components!
Risk of death via electric shock
Switch off printer with the main switch.
Securethemainswitchwithalock.
Hot surfaces!
Risk of burns
Wait at least 1 hour after switching off u ntil the UV lamps have cooled
down before at te mpting replacem en t.
Wear protective gloves.
Encoder ruler could be scratched!
Reduced functionality of the printer
Do not touch the encoder ruler with hard objects.
1. Switch off printer with the main switch.
2. Securethemainswitchwithalock.
3. Manually push the print carriage to a suitable position.
4. D i sco nnect printer from the p ower su pply.
5. Fold the corresponding front panel up.