EDAN F9 Express - User Manual

EDAN F9 Express
215 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EDAN Agile PLM Electronic Signature Information
--Signatures related to this document and performed in EDAN Agile PLM.
文件名称(Document Name):F9说明书_英文
文件编号(Number):01.54.107779
版本(Version):2.9
产品型号(Product Model):F9;F9 Express
项目编码(Project Code):2040A000
签批信息(Signature):
作者(Originator) : 周 睿 (zhourui) 2018-10-15 15:36:46
审核人(Reviewers) : 刘 小倩 (liuxiaoqian) 2018-10-15 17:03:21
审核人(Reviewers) : 唐 林 (tanglin) 2018-10-16 09:10:49
审核人(Reviewers) : 明 镭 (minglei) 2018-10-16 13:54:54
审核人(Reviewers) : 张 冬雪 (zhangdongxue) 2018-10-19 12:04:28
审核人(Reviewers) : 占 皓 (zhanhao) 2018-10-29 09:12:01
审核人(Reviewers) : 余 俊煜 (yujunyu) 2018-10-16 18:54:43
批准人(Approvers) : 夏 欢欢 (xiahuanhuan) 2018-11-02 10:35:44
批准人(Approvers) : 吴 明花 (wuminghua) 2018-11-07 14:20:44
批准人(Approvers) : 冀 伟 (jiwei) 2018-11-02 15:35:48
版权©深圳市理邦精密仪器股份有限公司 (Copyright©Edan Instrument,Inc.)

Table of Contents

Questions and Answers

  • V
    vanessa63Sep 23, 2025
    How to resolve issues with internal contractions monitoring on EDAN Medical Equipment?
    • G
      Gregory GatesSep 23, 2025
      To resolve issues with internal contractions monitoring on EDAN Medical Equipment, consider these steps: * If the intrauterine catheter is jammed, wash it with a disinfectant. * In a “dry” environment or if the tip of the intrauterine catheter is placed extraovularly, wash with disinfector or change the position of transducer. * If the zero adjustment is wrong, zero the system. * If there is a connector failure, move or contact the catheter. If there is no trend fluctuation, change the intrauterine cable.
  • T
    Tamara StevensAug 23, 2025
    Why is the recorder not working on my EDAN F9 Express Medical Equipment?
    • K
      Katherine HernandezAug 25, 2025
      If the EDAN Medical Equipment recorder isn't working, first, make sure the recorder has been started by pressing the PRINT key. Another cause could be that it has run out of paper, so load more paper. Also, ensure that the paper drawer is correctly locked by sliding it in until both latches are secured.
  • H
    hessannetteAug 25, 2025
    How to reduce noise on EDAN F9 Express Medical Equipment?
    • M
      Mallory Decker MDAug 26, 2025
      If you're experiencing noise with your EDAN Medical Equipment, try turning down the volume. If the volume isn't the issue, it might be interference from a mobile phone or another source. Keep any potential interfering sources away from the monitor.
  • N
    ngutierrezAug 27, 2025
    Why is the trace quality bad on my EDAN F9 Express?
    • M
      Mary WilliamsonAug 27, 2025
      If you're getting a bad trace quality or fluctuant TOCO baseline on your EDAN Medical Equipment, the belt might be too tight or too loose; try adjusting it. Also, if the belt has no elasticity, renew it. Maternal or frequent fetal movements can also cause this issue, so request the patient to calm down and stay still or delay the monitoring.
  • D
    Denise ChapmanAug 27, 2025
    Why is the trace inconstant on my EDAN F9 Express?
    • C
      curtisthomasAug 27, 2025
      If the EDAN Medical Equipment displays an inconstant trace or display, it could be due to several factors. If the patient is overweighted, monitor FHR with DECG. Ensure the ultrasound transducer is properly positioned for a better signal. Check for a loose belt and tighten it. Wipe off any superfluous aquasonic coupling gel, or use the recommended quantity if there is inadequate gel. Frequent fetal or maternal movements can also interfere; in these cases, delay monitoring or ask the patient to stay still.
  • J
    Jennifer HarrisSep 18, 2025
    What to do if my EDAN Medical Equipment has troubles with external contractions monitoring?
    • J
      Jared ThomasSep 18, 2025
      If your EDAN Medical Equipment experiences troubles with external contractions monitoring, first adjust the belt if it's too tight or too loose. If the belt has no elasticity, renew it. Maternal or frequent fetal movements can cause issues, so ask the patient to stay still or delay monitoring. If the body pressure from the uterus to the TOCO transducer is far higher than average, ensure favorable contact between the patient's skin and the TOCO transducer, and change its position if necessary.
  • M
    Michele JacobsSep 14, 2025
    How to reduce noise from EDAN F9 Express Medical Equipment?
    • D
      David CareySep 14, 2025
      To reduce noise from EDAN Medical Equipment, first, turn down the volume if it is set too high. If the noise is due to interference from a mobile phone or other electromagnetic source, turn off or move the source. Additionally, try moving the monitor to a location with less interference.
  • A
    Anthony MooreSep 15, 2025
    Why is there big ECG signal interference or a thick baseline on my EDAN Medical Equipment?
    • M
      Mary BauerSep 15, 2025
      Big ECG signal interference or a thick baseline on EDAN Medical Equipment might be due to abnormal electrode placement or invalid electrodes; check the placement and validity. Also, ensure the cable connector is well connected. Verify that the power socket has a standard ground wire and that the special ground wire connecting with the monitor is properly earthed.
  • J
    jacquelinebarnesSep 5, 2025
    How to correct the time and date on EDAN F9 Express Medical Equipment?
    • M
      Matthew WebbSep 5, 2025
      If you find that the time and date are incorrect on your EDAN Medical Equipment, it may be because the time was incorrectly set. Reset the time and date, and note the difference between Daylight Saving Time and Winter Standard Time. If that doesn't solve the problem, the battery may be faulty, and service personnel should be called.
  • A
    Angela HopkinsSep 3, 2025
    Why only IUP peak but no baseline on EDAN Medical Equipment?
    • L
      Lisa ReynoldsSep 3, 2025
      If you're seeing only the IUP peak but no baseline on your EDAN Medical Equipment, the zero adjustment might be incorrect. Try zeroing the system.

Summary

Chapter 1 Safety Guidance

Instruction for Safe Operation

Outlines critical safety instructions and guidelines for proper and safe use of the device.

Safety Precautions

Lists critical warnings and precautions to prevent injury or damage during instrument operation.

Chapter 2 Introducing the Monitor

Installation Guide

Provides step-by-step instructions for setting up and installing the monitor.

Chapter 4 Alarms

Chapter 6 Pre-Monitoring Preparation

Loading Recorder paper

Provides step-by-step instructions for loading the thermal printer paper correctly.

Switching On the Monitor

Details the procedure for powering on the monitor and checking its initial state.

Connecting Transducers

Provides instructions on how to properly connect various transducers to the monitor.

Chapter 7 Fetal Monitoring

Chapter 9 Maternal Monitoring (F9 Express)

Maternal NIBP Monitoring

Explains how to perform non-invasive blood pressure (NIBP) monitoring.

Chapter 12 Maintenance and Cleaning

Appendix 3 Troubleshooting

NIBP and SpO2 No Results

Troubleshooting steps when NIBP or SpO2 measurements yield no results.

EDAN F9 Express Specifications

General IconGeneral
Waterproof RatingIPX1
BatteryRechargeable lithium-ion battery
CategoryFetal and Maternal Monitor
FHR Measurement Range50 to 240 bpm
FHR Accuracy±1 bpm
Ultrasound Frequency1 MHz
Battery LifeApprox. 4 hours
PrintingThermal printer
Paper Speed1, 2, 3 cm/min
InterfacesUSB, RS-232
ParametersFHR, TOCO
Power Supply100-240 V~ 50/60 Hz
WeightApproximately 3.5 kg
PrintoutReal-time and recall printout
Display12.1-inch color TFT LCD screen, folding up to 90 degrees

Related product manuals