Inlet filters
M588-08-880 Issue D
4.5 Maintenance
Note: It is recommended that the Solberg Vacuum Filters Maintenance Manual supplied by the OEM is read and
adhered to in order to protect the equipment and reduce personal risk.
Ensure maintenance is carried out by a suitably trained and supervised technician in accordance with local
and national safety requirements and that they are familiar with the safety procedures that relate to this
filter.
Check that all the required parts are available and of the correct type before work is started.
Do not re-use seals and gaskets.
Where an inlet butterfly valve is present, ensure this is isolated before maintenance work begins on the inlet
filter.
Leak test the system after maintenance work is complete if you have connected or disconnected any vacuum
joints. Seal any leaks that are found.
4.6 Storage and disposal
4.6.1 Storage
If the inlet filter will not be used immediately:
1. Refit the protective covers over the inlet and outlet ports.
2. Place the Filter in its protective packaging.
3. Store in a cool dry place.
4.6.2 Disposal
Dispose of the inlet filter and any components removed from in accordance with local and national safety and
environmental requirements.
Particular care must be taken with the following:
1. Fluoroelastomers that may have been subjected to temperatures above 260 °C (refer to Section 4.2).
2. Components that have been contaminated with dangerous process substances.