Temperature transmitter
M588-08-880 Issue D
9.4 Installation
9.4.1 Unpack and inspect
Note: The information contained within this manual covers the physical installation of the accessory only. It will
also be necessary to configure the GXS pump controller to recognise the accessory after it has been
installed. Please refer to the GXS product manual for further information.
Remove all the packaging materials and check the temperature transmitter for signs of damage. If the temperature
transmitter is damaged, notify your supplier and the carrier in writing within three days; state the Item number of
the temperature transmitter together with your order number and your supplier's invoice number. Do not use the
temperature transmitter if it is damaged.
Check that your package contains the correct items. If any of the items are missing, notify your supplier in writing
within three days.
If the temperature transmitter is not to be used immediately, store as described in Section 9.5.
9.4.2 Installation of the temperature transmitter
9.4.2.1 To the pump inlet spool
Install the temperature transmitter assembly as follows:
1. Remove the ½ inch BSP tapered plug from the relevant instrument port in the inlet spool.
2. Clean and remove all traces of old thread sealant from the instrument port.
3. Check that the temperature transducer assembly has a ½ inch BSP male connector fitted.
4. Apply a thin coat of Loctite 577 thread sealant to the ½ inch BSP tapered thread on the male connector.
5. Refer to Figure 86 and Figure 87. Screw the temperature transducer into the instrument port.
Note: The body of the temperature transmitter may be rotated to any position before the fitting is fully
tightened.
Table 63 - Other
Parameter Data
Control voltage Nominal 24 V
Signal output 4 mA to 20 mA
Cable entry PG16
Design pressure 1 barg/FV (mechanical integrity 10 barg)
Operating temperature -20 °C to +200 °C