Temperature transmitter
Figure 87 - Installation of the temperature transmitter to the pump inlet spool
9.4.2.2 To the spool between the pump and booster
Install the temperature transmitter assembly as follows:
1. Remove the 3/8 inch BSP plug from the relevant instrument port in the spool.
2. Ensure the 3/8 inch BSP instrument port is clean.
3. Check that the temperature transducer assembly has a 3/8 inch BSP male connector fitted.
4. Apply a thin coat of Loctite 577 thread sealant to the 3/8 inch BSP tapered thread on the male connector.
5. Refer to Figure 86 and Figure 88. Screw the temperature transducer into the instrument port.
Note: The body of the temperature transmitter may be rotated to any position before the fitting is fully
tightened.
Figure 88 - Installation of the temperature transmitter to the spool between the pump and booster