120
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → ARC SET → USER MESSAGE → ALARM EVENT → DISABLE
OK → CONFIGURATION → ARC SET → USER MESSAGE → ARMED EVENT → DISABLE
OK → CONFIGURATION → ARC SET → USER MESSAGE → DISARMED EVENT → DISABLE
OK → CONFIGURATION → ARC SET → USER MESSAGE → EXT. PWR LOSS EV → DISABLE
OK → CONFIGURATION → ARC SET → USER MESSAGE → EXT. PWR REST EV → DISABLE
OK → CONFIGURATION → ARC SET → USER MESSAGE → BATTERY STATUS EV → DISABLE
OK → CONFIGURATION → ARC SET → USER MESSAGE → TEST EVENT → DISABLE
EKB3
Enter parameter 25, event number & parameter status value:
[25010#] - Alarm Event
[25020#] - Disarmed Event
[25030#] - Armed Event
[25040#] - Main Power Loss Event
[25050#] - Main Power Restore Event
[25060#] - Backup Battery Status Event
[25070#] - Test Event
This command disables particular User Messages.
Disable User Messages
SMS
N/A
EKB2
Menu path:
OK → CONFIGURATION → ARC SET → ACCOUNT → [XXXX]
Value: [XXXX] – 4 digit account ID code, range – [0000... 9999]
EKB3
Enter parameter 27 & account ID code
[27xxxx#]
Value: xxxx – 4 digit account ID code, range – [0000... 9999]
Account is an alarm system ID code required for identication by monitoring station. This ID
code is transmitted via data message allowing the monitoring station to identify the alarm
system device. The default Account ID 9999 must be changed.
Account (Alarm
System ID)