EasyManua.ls Logo

Emerson Fisher FLOBOSS 407

Emerson Fisher FLOBOSS 407
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FloBoss 407 Instruction Manual
Rev 5/00 G-5
R
Rack — For a ROC or FloBoss, a rack is a row of slots into which I/O modules may be plugged.
The rack is given a letter to physically identify an I/O channel location, such as “A” for the first
rack. Built-in I/O channels are assigned a rack identifier of “A,” while diagnostic I/O channels
are considered to be in rack “E”.
RAM — Random Access Memory. In a ROC or FloBoss, it is used to store history, data, most user
programs, and additional configuration data.
RBX — Report-by-exception. In a ROC or FloBoss, it always refers to spontaneous RBX in which
the ROC/FloBoss contacts the host to report an alarm condition.
RFI — Radio frequency interference.
RI — Ring Indicator modem communications signal.
ROC — Remote Operations Controller, Fisher Control’s microprocessor-based unit that provides
remote monitoring and control.
ROCLINK — Configuration software used to configure ROC or FloBoss units to gather data, as
well as most other functions.
ROCPAC Module — ROM and RAM module that contains the operating system, applications
firmware, and communications protocol in a ROC300-Series unit.
ROM — Read-only memory. Typically used to store firmware. Flash memory.
RTC — Real-time clock.
RTD — Resistance Temperature Detector.
RTS — Ready to Send modem communications signal.
RTU — Remote Terminal Unit.
RTV — Room Temperature Vulcanizing, typically a sealant or caulk like silicone rubber.
RXD — Received data communications signal.
S
SAMA — Scientific Apparatus Makers Association.
Script — A uncompiled text file (such as keystrokes for a macro) that is interpreted by a program
to perform certain functions. Typically, scripts can be easily created or edited by the end-user to
customize the software.
Soft Points — A type of ROC point with generic parameters that can be configured to hold data as
desired by the user.
SP — Setpoint, or Static Pressure.
SPI — Slow Pulse Input.
SPK — Speaker.
SRAM — Static Random Access Memory. Stores data as long as power is applied; typically
backed up by a lithium battery or supercapacitor.
SRBX – Spontaneous Report-By-Exception. Refer to RBX.
SVA — Signal Value Analog.
SVD — Signal Value Discrete.
T-Z
TDI — Timed Discrete Input, or Timed Duration Input.
TDO — Timed Discrete Output, or Timed Duration Output.
Tf — Flowing temperature.
TLP — Type (of point), Logical (or point) number, and Parameter number.
TXD — Transmitted data communications signal.

Table of Contents

Related product manuals