Performing soft system resets — CrossPoint Ultra and MAV Plus
88, 128, 816, 164, 168, 1212, 1616, 248, and 328 matrix sizes
See the following table fo
r a summary of the reset modes, comparable to IPL resets
3, 4, and 5
.
C
Review the reset modes carefully. Using the wrong reset mode may result
in unintended loss of flash memory programming, port reassignment, or a
controller reboot.
N
The reset modes listed below close all open IP and Telnet connections and close
all sockets. Also, the following modes are separate functions, not a continuation
from Mode 1 to Mode 5.
Reset Mode Comparison/Summary
Mode Activation Result Purpose/Notes
3
Hold down the Reset button for about
3 seconds, until the Reset LED blinks
once, then press Reset momentarily
(<1 second) within 1 second.
Mode 3 turns events on or off. During resetting,
the Reset LED flashes 2 times if events are starting,
3 times if events are stopping.
Mode 3 is useful for
troubleshooting.
4
Hold down the Reset button for
about 6 seconds, until the Reset LED
blinks twice (once at 3 seconds and
again at 6 seconds). Then press Reset
momentarily (<1 second) within 1
second.
Mode 4:
Enables ARP capability.
Sets the IP address to the factory default.
Sets the subnet address to the factory default.
Sets the gateway address to the factory default.
Sets port mapping to the factory default.
Turns DHCP off.
Turn events off.
The Reset LED flashes four times in quick
succession during the reset.
Mode 4 enables you
to set IP address
information using ARP
and the MAC address.
5
Hold down the Reset button for
about 9 seconds, until the Reset LED
blinks three times (once at 3 seconds,
again at 6 seconds, and then again
at 9 seconds). Then press Reset
momentarily (<1 second) within 1
second.
N
Mode 5 reset clears most
adjustments. To save these
settings, use the Windows-
based Matrix Switchers
Control Program and the
File > Save MATRIX
settings as... selection before
you perform this reset (See
chapter 5, “Matrix Software”).
Mode 5 performs a complete reset to factory
defaults (with the exception of the firmware):
Does everything mode 4 does.
Resets almost all real time adjustments:
clears all ties and presets, clears all audio or
RS-232 mutes, clears all I/O grouping, clears
all RGB delay settings to zero, and clears all
input and output audio settings.
Resets all IP options.
Removes/clears all files for the switcher.
The reset LED flashes four times in quick
succession during the reset.
Mode 5 is useful if
you want to start over
with configuration and
uploading and also to
replace events.
For different reset levels, press and hold the button while the switcher is running or
press and hold the button while you apply power to the switcher.