Drives
138
3.
DRIVES
Single-drives
· 116 ·
Ref.2003
· 116 ·
QC-PDS
HARDWARE
A18 connector.
+24 V DC electric power supply input
Male 2-pin connector located under the left side of the unit behind the lid
and identified as A18.
Female aerial plug connector (dual input) with clamping yoke supplied as
an accessory. It is used to supply +24 V DC auxiliary power supply to the
control electronics of the drive connected to the DC BUS.
The following table shows the main data of the aerial connector and the
wire to be connected:
Pinout
Pin description
Installation
Connector data
Nr of poles
2 / 90°|270°
Gap (mm) 5.08
Min./max. tightening torque (N·m) 0.4/0.5
Flat screwdriver, size (mm) 0.6 x 3.5
Min./max. allowed cross-section (mm²) 0.2/2.5
Current (A)
< 15
Connection data
Length to strip (mm) 7
Wire cross-section (mm²) 2.5
F. H3/49
A18 connector. Pinout.
T. H3/25
A18 connector. Pin description.
Pin Signal Description
+24V
+24 V DC +24 V DC voltage input
GND
0 V DC Reference 0 V DC
F. H3/50
A18 connector. +24 V DC connections among units.
+24V
GND
+24V
GND
+24V
GND
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²