Cables
7.
CABLES
Mains connection cables
· 216 ·
230
Ref.2003
QC-PDS
HARDWARE
7.1 Mains connection cables
The MPC-4xS-
M range of multi-pole power cables supplied by FAGOR
to establish the connection between the mains and the main power supply
(via the MAINS FILTER if it is not regenerative or the CHOKE if it is
regenerative) is shown in the tableT. H7/2. They are supplied without
connectors. The number of cable meters is available on request. Available
lengths: 5, 10, 15, 20, 30, 35, 40, 50, 75, 100, 150, 200, 250 and 300
meters for cross sections of up to 10 mm², inclusive. For all other
sections, only up to 100 m.
The range of MPC-1xS-
M single-pole power cables supplied by FAGOR
to establish the connection between the mains and the main power supply
(via the CHOKE if it is regenerative) is shown in the table T. H7/3. These
are supplied without any pins. The number of cable meters is available on
request. Available lengths: 5, 10, 15, 20, 25, 30, 35, 40, 45 and 50 meters
for 95, 120 y 150 mm² sections.
Characteristics
T. H7/2
Range of
multi-pole
mains connection cables. Outside diameter.
Reference
e approx.
Reference
e approx.
MPC-4x1,5-
M 9.1 mm MPC-4x16-
M21.6 mm
MPC-4x2,5-
M 10.6 mm MPC-4x25-
M25.2 mm
MPC-4x4-
M 11.9 mm MPC-4x35-
M28.6 mm
MPC-4x6-
M 14.5 mm MPC-4x50-
M33.4 mm
MPC-4x10-
M 17.5 mm MPC-4x70-
M42.5 mm
MPC-4xS, S: cross sectional area.
M: Length in m.
e approx.: Approximate
outside diameter of the cable.
T. H7/3
Range of
single-pole
mains connection cables. Outside diameter.
Reference
e approx.
Reference
e approx.
MPC-1x
95
-
M 22.0 mm MPC-1x
150
-
M25.8 mm
MPC-1x
120
-
M 23.6 mm
MPC-1xS,
S
: cross sectional area.
M: Length in m.
e approx: Approximate
outside diameter of the cable.
Reference
MPC-4x
S
-
M
e approx. See table
T. H7/2
Type Shielded. It ensures EMC compatibility.
Flexibility
High. Specifically for cable-carrying chains with a
minimum bending radius for dynamic 7.5x
e
conditions (up to 16 mm²) and 10x
e (from 25 mm²)
and static conditions 4x
e.
Covering
PUR. Polyurethane resistant to chemicals used in
machines/tools.
Permissible
temperature range
Work: -40°C/+80°C (-40°F/+176°F)
Storage: -50°C/+90°C (-58°F/+194°F)
Rated
voltage
VDE Uo/U: 600/1000 V
UL/CSA 1000 V
Reference
MPC-1x
S
-
M
e approx. See table
T. H7/3
Type Shielded. It ensures EMC compatibility.
Flexibility
High. Specifically for cable-carrying chains with a
minimum bending radius for dynamic 7.5x
e and
static 3x
e conditions.
Covering
PUR. Polyurethane resistant to chemicals used in
machines/tools.
Permissible
temperature range
Work: -5°C/+90°C (+23°F/+194°F)
Storage: -40°C/+90°C (-40°F/+194°F)
Rated
voltage
VDE Uo/U: 600/1000 V
UL/CSA 600 V