Auxiliary modules
4.
AUXILIARY MODULES
External Auxiliary Power Supplies
174
Ref.2003
· 156 ·
QC-PDS
HARDWARE
4.6.2 Technical data
Electrical data
Environmental conditions and mechanical specifications
T. H4/12
External auxiliary power supplies. Size |0. Width: 39 mm. Electrical data.
Model QC-APS-15 QC-APS3-15
24 V DC power supply
INPUT
Line voltage
3-ph, between 400 (1-10 %) V AC and 480 (1+10 %) V AC
Line frequency
48 ... 62 Hz
Nominal current 0.65 A 0.65 A
Rated power 450 W 450 W
OUTPUT
Voltage
+24 V DC (1± 5 %) +24 V DC (1± 5 %)
Rated current 15 A 15 A
Rated power
360 W 360 W
Voltage range at the DC BUS 500/800 V DC 500/800 V DC
Soft-start circuit
Soft-load circuit of the DC BUS
NO YES
Maximum admissible capacity
-15 mF
Maximum load current
-8 A
Snubber circuit
Motor protection circuit NO YES
Maximum admissible power - 160 W
WARNING.
The QC-APS-15 and QC-APS3-15 auxiliary power supplies supports
a line voltage of up to 480 (1+10 %) V AC.
T. H4/13
External auxiliary power supplies. Environmental conditions and mechanical specifications.
Model QC-APS-15 QC-APS3-15
Operating ambient temperature 5 °C / 45 °C (41 °F / 113 °F)
Storage temperature -25 °C / +70 °C (-13 °F / +158 °F)
Relative humidity < 90 % (non condensing at 45 °C / 113 °F)
Maximum altitude for installation 2 000 m (6 561 ft) asl
Operating vibration 1 g
Shipping vibration 1.5 g
Sealing degree Open IP xx *
Size 0 0
Width in mm/ in 39.0 / 1.5 39.0 / 1.5
Approx. mass in kg/lb 3.6 / 7.9 3.6 / 7.9
*
Open IP xx
, to be installed inside a cabinet or assembly that provides the required access protection.
INFORMATION. In case of micro-surges or total mains power outage, this module ensures
the stability of the +24 V DC to feed the control circuits of the drives connected to the DC
BUS and maintain it for as long as the emergency stop of the motors lasts, thusstopping the
axes in a controlled manner. This is what is known as dynamic braking.
i