Cables
7.
CABLES
Power cables. DRIVE|MOTOR connection
· 220 ·
230
Ref.2003
QC-PDS
HARDWARE
7.2.2 Single-pole cables
The range of MPC-1xS-
M single-pole power cables supplied by FAGOR
to establish the connection between the motor and the drive is shown in
the table T. H7/6.
These are supplied without any pins. The number of cable meters is
available on request. Available lengths: 5, 10, 15, 20, 25, 30, 35, 40, 45 and
50 meters for 95, 120 y 150 mm² sections.
Supplied without terminals
on the end and only upon request Therefore,
before making the connection, the corresponding terminals must be mount-
ed on the cable ends.
Characteristics
Selection
The required cable used to make the power connection between the drive
and the corresponding motor is shown in the motor-drive matching tables
in chapter 5. SELECTING CRITERIA of this manual.
Installation
See section, 8.5.3 MOTOR POWER CONNECTION.
T. H7/6
Range of single-pole power cables. Outside diameter.
Reference
e approx.
Reference
e approx.
MPC-1x
95
-
M 22.0 mm MPC-1x
150
-
M25.8 mm
MPC-1x
120
-
M 23.6 mm
MPC-1x
S
, S: cross sectional area.
M: Length in m.
e approx: Approximate
outside diameter of the cable.
INFORMATION. With regard to the motor, keep in mind that it refers to
motors cataloged by FAGOR and listed in the tables under section «motor-
drive matching» in chapter 3. DRIVES of this manual.
MANDATORY. In order for the system to comply with the European
Directive on Electromagnetic Compatibility, the single-pole cable must be
shielded and also the shield must be connected at both ends; in other words,
both at the drive end and a the motor end. This condition is a must.
i
Reference
MPC-1x
S
-
M
e approx. See table
T. H7/6
Type Shielded. It ensures EMC compatibility.
Flexibility
High. Specifically for cable-carrying chains with a
minimum bending radius for dynamic 7.5x
e and
static 3x
e conditions.
Covering
PUR. Polyurethane resistant to chemicals used in
machines/tools.
Permissible temperature
range
Work: -5°C/+90°C (+23°F/+194°F)
Storage: -40°C/+90°C (-40°F/+194°F)
Rated
voltage
VDE Uo/U: 600/1000 V
UL/CSA 600 V
single-pole cable