HARDWARE
3.1.2 Technical data
The nominal and peak output currents for feed axis single-drives for 400 V AC line voltages and 4/8
kHz IGBT switching frequencies are shown in the tables below. Note that: 1 kW = 1.34 hp.
The output currents for S1 and S6-40% duty cycles for spindle single-drives
for 400 V AC line voltages
and 4/8 kHz IGBT switching frequencies are shown in the tables below. Note that: 1 kW = 1.34 hp.
T. H3/1
Single-drive for feed axis servomotor control. fc = 4 kHz. Internal ventilation.
QC-DR- 007 012 021 030 040 055 080 120
In (A) 3.5 6.0 10.5 15.0 20.0 27.5 40.0 60.0
Ip (A)
7.0 12.0 21.0 30.0 40.0 55.0 80.0 120.0
Pcal (kW)
2.4 4.2 7.3 10.4 13.9 19.1 27.7 41.6
Pcal (hp) 3.3 5.6 9.8 13.9 18.6 25.5 37.1 55.7
T. H3/2
Single-drive for feed axis servomotor control. fc = 8 kHz. Internal ventilation.
QC-DR- 007 012 021 030 040 055 080 120
In (A) 3.5 5.4 9.8 15.0 20.0 21.0 40.0 60.0
Ip (A) 7.0 10.8 19.6 30.0 40.0 42.0 80.0 120.0
Pcal (kW) 2.4 3.7 6.7 10.4 13.9 14.5 27.7 41.6
Pcal (hp) 3.3 4.9 9.0 13.9 18.6 19.4 37.1 55.7
T. H3/3
Single-drive for spindle motor control. fc = 4 kHz. Internal ventilation.
QC-DR- 030 040 055 080 120 275
IS1 (A)
23.1 30.8 42.3 61.5 92.3 245.5
0.7xIS1 (A) 16.1 21.5 29.6 43.0 64.6 171.8
IS6-40% (A) 30.0 40.0 55.0 80.0 120.0 275.0
PS1 (kW) 16.0 21.3 29.3 42.6 64.0 170.1
PS1 (hp)
21.4 28.6 39.3 57.2 85.7 228.0
PS6-40% (kW)
20.8 27.7 38.1 55.4 83.1 190.5
PS6-40% (hp) 27.9 37.1 51.1 74.3 111.4 255.4
T. H3/4
Single-drive for spindle motor control. fc = 8 kHz. Internal ventilation.
QC-DR- 030 040 055 080 120 275
IS1 (A) 17.5 22.0 30.0
48.0 70.0
154.0
0.7xIS1 (A) 12.2 15.4 21.0 33.6 49.0 107.8
IS6-40% (A) 22.8 28.6 39.0 62.4 91.0 169.4
PS1 (kW) 12.1 15.2 20.8 33.2 48.5 106.7
PS1 (hp)
16.2 20.4 27.9 44.5 65.0 143.0
PS6-40% (kW)
15.7 19.8 27.0 43.2 63.0 117.3
PS6-40% (hp)
21.0 26.5 36.2 57.9 84.4 157.2