Drives
138
3.
DRIVES
Dual-drives
· 128 ·
Ref.2003
· 128 ·
QC-PDS
HARDWARE
3.3.6 Connectors
Distribution
See section, 3.3.1 OUTSIDE LOOK.
Function
X11A|X11B connectors.
Power connection of the A|B axis servomotors
Male 3-pin connectors located on top of the drive and identified as
X11A|X11B.
The following table shows the main data of the aerial plug connectors and
the conductors to be connected based on the drive:
QC-DR-07+07-FD2 | QC-DR-12+12-FD2
Female aerial plug connectors with screw connection with tension sleeve
and lock and release lever (automatic latching) supplied as accessories.
They are used for the motor power connections. Accordingly, these
connectors will be provided for the indicated models to power the motor.
QC-DR-21+21-FD2 | QC-DR-30+30-FD2
Female aerial plug connectors with screw connection with tension sleeve
and automatic click and lock system supplied as accessories. They are
used for the motor power connections. Accordingly, these connectors will
be provided for the indicated models to power the motor.
Pinout
The pinout is printed on the connectors as U-V-W.
Installation
See section, 8.5.3 MOTOR POWER CONNECTION.
NOTE. All the connectors of the unit are polarized and they can only be
connected in one position to avoid any inverted connections.
Connector data
Nr of poles 3
Gap (mm) 7.62
Min./max. tightening torque (N·m)
0.5/0.6
Flat screwdriver, size (mm)
0.6 x 3.5
Minimum section (mm²)
See table
T. H3/27
Maximum section permitted (mm²) 2.5
Maximum nominal input current (A)
6
Connection data
Length to strip (mm)
8
Connector data
Nr of poles 3
Gap (mm) 7.62
Min./max. tightening torque for S
4 mm² (N·m) 0.5/0.6
Min/max tightening torque for S
4 mm² (N·m) 0.7/0.8
Flat screwdriver, size (mm) 0.6 x 3.5
Minimum section (mm²)
See table
T. H3/27
Maximum section permitted (mm²)
6
Maximum nominal input current (A) 15.0
Connection data
Length to strip (mm) 10