Drives
138
3.
DRIVES
Single-drives
· 90 ·
Ref.2003
· 90 ·
QC-PDS
HARDWARE
3.1.4 Derating curves
The following graphs show the maximum effective current in continuous S1
(In) and intermittent (Imax.) duty cycles. depending on the switching
frequency of the power transistors within a temperature range of 5 °C and
55 °C (41 °F and 131 °F).
See section, 3.1.3 LOAD DUTY CYCLES.
Single-drives
QC-DR-007-F
QC-DR-012-F
QC-DR-021-F
for switching frequencies of fc = 4 kHz
F. H3/8
Current derating at 4 kHz.
QC-DR-007-F
single-drive for feed axis.
F. H3/9
Current derating at 4 kHz.
QC-DR-012-F
single-drive for feed axis.
F. H3/10
Current derating at 4 kHz.
QC-DR-021-F
single-drive for feed axis.
A
7 . 0
3 . 5
3 5 / 9 5 5 5 / 1 3 1
° C / ° F
I
N
I
M A X
4 5 / 1 1 3
4 0 / 1 0 4
5 0 / 1 2 2
QC-DR-007-F
·
feed axis
·
Tamb. I
N
Imax.
°C °F A A
35 95 3.5 7.0
40 104 3.5 7.0
45 113 3.5 7.0
50 122 3.3 6.6
55 131 3.1 6.2
A
1 2
6
3 5 / 9 5 5 5 / 1 3 1
° C / ° F
I
N
I
M A X
4 5 / 1 1 3
4 0 / 1 0 4
5 0 / 1 2 2
QC-DR-012-F
·
feed axis
·
Tam b. I
N
Imax.
°C °F A A
35 95 6.0 12.0
40 104 6.0 12.0
45 113 6.0 12.0
50 122 5.6 11.2
55 131 5.3 10.6
A
2 1 . 0
1 0 . 5
3 5 / 9 5 5 5 / 1 3 1
° C / ° F
I
N
I
M A X
4 5 / 1 1 3
4 0 / 1 0 4
5 0 / 1 2 2
QC-DR-021-F
·
feed axis
·
Tam b. I
N
Imax.
°C °F A A
35 95 10.5 21.0
40 104 10.5 21.0
45 113 10.5 21.0
50 122 10.5 21.0
55 131 10.5 21.0