Connection of the control and communications signals
302
Ref.2003
· 300 ·
QC-PDS
HARDWARE
8.6.12 Connections for SBC · Safe Brake Control · control signals
All information regarding the X34 connector can be found in chapter 3.
DRIVES.
NOTE. Only available for QC-DR-275-SS2 models.
MANDATORY. ALWAYS
make the connections using:
0.5 mm² cross-sectional conductors using a 10 mm sleeveless ferrule
.
Maximum length of the stripped end, 8 mm.
or
0.34 mm² cross-sectional conductors using a 14.5 mm sleeved ferrule
.
Length of ferrule, 10 mm. Maximum length of the stripped end, 12 mm.