Drives
DRIVES
Status indicator LED's
3.
Ref.2003
· 119 ·
QC-PDS
HARDWARE
3.2 Status indicator LED's
For models QC-DR-
-F
Single QC-DR-
-F
drives by FAGOR have four status indicator LEDs.
D8|D9 status leds
Configuration and error status leds.
D10|D11 status leds
Status LEDs for Ethernet communication and SERCOS-III interface.
Modes Meaning
OFF
ON
Blinking with t ON at 20 %
Blinking with t ON at 80 %
Left (led D8) / right (led D9) alternate blinking
Error
D8 D9 Meaning
Initial state.
Equipment is not
configured.
Equipment configured with
SERCOS-III communication and
without voltage in the DC BUS
Equipment configured with
SERCOS-III communication and
voltage + DC BUS is not enabled
Equipment configured with
SERCOS-III communication and
voltage + DC BUS is enabled.
Error status
Internal code error.
Miniboot error, non-DSP version
axis 2 configured
axis 2 not configured
axis 2 configured
axis 2 not configured
No. of blinks =
Error group No.
INFORMATION.
Display the error codes on the QUERCUS CNC screen.
INFORMATION.
LEDs D10|D11 indicate the status of the transmission between two units
using a SERCOS-III connection. The information on these LEDs must
ONLY be interpreted on the unit connected in B10B.
Led Name Status Meaning
D10 LINK
ON Physical connection established
OFF No connection
D11 ACTIVITY
OFF No activity
LIT FIXED
(not blinking)
Establishing SERCOS-III communication
·active port·
Blinking
2 Hz. Software update procedure or
inactive port.
4 Hz. SERCOS-III communication
established ·active port·