Installation
8.
INSTALLATION
Location
302
Ref.2003
· 238 ·
QC-PDS
HARDWARE
8.1.3 Climatic considerations
The temperature inside the electrical cabinet containing the QC-PDS
system must not exceed 55 °C (131 °F).
The modules generate heat and when trying to decide whether the
electrical cabinet containing the QC-PDS system needs external cooling
or not, one must know the power dissipated by each one of its modules.
Refer to the table below to check the power dissipated by each element.
MANDATORY. NEVER install the QC-PDS system next to a heat source.
T. H8/1
Dissipated power.
Non-regenerative
power supplies
power dissipated at maximum load
QC-PS-025 180 W
QC-PS-045 250 W
Regenerative
power supplies
power dissipated at maximum load
spindle S1
spindle S6-40%
crest/mean
QC-RPS-030-F
420 W
570/315 W
QC-RPS-160-
1860 W 2100/1200 W
Auxiliary modules power dissipated at maximum load
QC-APS-15 63 W
QC-APS3-15 63 W
QC-CM-75 0 W
QC-BPM-100 5 W
ER+TH-18/
It depends on the activation frequency
of the Ballast protection circuit
ER+TH-18/
+FAN
MAIN FILTER 42A-A 15 W
MAIN FILTER 75A-A 20 W
MAIN FILTER 275 50 W
Single-drive
power dissipated at maximum load.
axis4|8 kHz spindle S1
spindle S6-40%
crest/mean
QC-DR-007-F
30/42 W
xx
QC-DR-012-F
53/68 W
xx
QC-DR-021-F
72/102 W
xx
QC-DR-030-F
100/145 W 157 W 220 W
QC-DR-040-F
142/201 W 213 W 301/202 W
QC-DR-055-F
190/210 W 293 W 404/310 W
QC-DR-080-F
255/370 W 405 W 560/305 W
QC-DR-120-F
390/560 W 615 W 864/465 W
QC-DR-275-
x
1860 W 2100/1200 W
Dual-drive
power dissipated at maximum load
axis 4|8 kHz
spindle S1 spindle S6-40%
QC-DR-07+07-FD2
39/55 W
xx
QC-DR-12+12-FD2
69/88 W
xx
QC-DR-21+21-FD2
93/132 W
xx
QC-DR-30+30-FD2
96/140 W
xx