Auxiliary modules
4.
AUXILIARY MODULES
Mains Filters
174
Ref.2003
· 140 ·
QC-PDS
HARDWARE
4.1 Mains Filters
In order to comply with European Directive 2014/30/EU on
Electromagnetic Compatibility, it is mandatory to insert a mains filter.
Particularly, the standard IEC 61800-3 for category C3 and the standard
IEC 61800-5-2 for immunity.
The main filters included in the FAGOR catalog and required for QC-PDS
systems are the MAIN FILTER
A-A.
These are installed between mains and the QC-PDS system and whose
main purpose is to reduce conducted disturbances caused by the drive
down to the levels indicated under the aforementioned standard and, at
the same time, make it immune to transient over-voltage like bursts or
voltage pulses.
4.1.1 Outside appearance
4.1.2 Technical data
F. H4/1
Mains filters. Outside appearance.
MAIN FILTER 42A-A
MAIN FILTER 75A-A
MAIN FILTER 275A
T. H4/1
Mains filters. Technical data.
MAIN FILTER
42A-A 75A-A 275A
Three-phase power supply 380-480 V AC (50/60 Hz)
Rated current (A)
(rating @ 50 °C/122 °F)
42 75 275
Approx. mass (kg/lb)
2.8/6.2 4.0/8.81
13.8/30.4
Rated leak current (mA) 0.50 0.50 < 80
Max. leak current (mA) 27 27 600
Power loss (W) 19 20 42
Sealing degree
IP 20 IP 20 IP 20
T. H4/2
Phase connection terminals Technical data.
MAIN FILTER
42A-A 75A-A 275A
Max. tightening torque (N·m)
1.8 2.3 24
Terminals Smin./Smax.
1/10 0.5/25
*
*
Without terminals. 6
10 mm holes with M10x20.4 screw and M10x1.8 bots
for power cable connection terminals.