Drives
DRIVES
Single-drives
3.
Ref.2003
· 87 ·
QC-PDS
HARDWARE
Electrical data
T. H3 /5
Single-drives.
Size|1.
Width:
78 mm.
Electrical data.
QC-DR-
-F
007 012 021 030 040 055
DC BUS voltage 565-800 V DC
Power to control circuits 24 V DC (between 21 V DC and 28 V DC)
Consumption of the control circuits (24 V DC)
0.7 A 0.7 A 0.9 A 0.9 A 0.9 A 0.9 A
Speed feedback Encoder
Controlling method PWM, AC sinewave, vector control
Interface
Inline Ethernet, digital SERCOS-III BUS
Displays the Ethernet interface status D10/D11 leds
Displays the drive status
LEDs D8/D9 · only for QC-DR-
-
F
models ·
Protections
Over-voltage, over-current, over-speed, heatsink
temperature, CPU temperature, motor temperature,
hardware error, overload.
Min. cross-section (mm²) for the power conductors
according to EN 60204-1, table 6 method B2
*
for
axis / for spindle
0.75/- 0.75/- 1.5/- 2.5/4.0 4.0/6.0 6.0/16.0
Max. allowable cross-section (mm²)
of flexible cable connector
2.5 6.0 16.0
Rated output frequency for X11A 0-550 Hz
**
Current bandwidth 800 Hz
Speed bandwidth
100 Hz · depends on the motor/drive set ·
*
The recommended cross-section depends on the rated operating power of the connected motor.
**
Equal to or higher than 550 Hz, only for QC-DR-...-
MDU
(dual-use).
T. H3 /6
Single-drives.
Size|3.
Width:
156 mm.
Electrical data.
QC-DR-
-F
080 120
DC BUS voltage 565-800 V DC
Power to control circuits 24 V DC (between 21 V DC and 28 V DC)
Consumption of the control circuits (24 V DC) 1.2 A 1.2 A
Speed feedback Encoder
Controlling method PWM, AC sinewave, vector control
Interface Inline Ethernet, digital SERCOS-III BUS
Displays the Ethernet interface status D10/D11 leds
Displays the drive status D8/D9 leds
Protections
Over-voltage, over-current, over-speed, heatsink
temperature, CPU temperature, motor temperature,
hardware error, overload.
Min. cross-section (mm²) for the power conductors
according to EN 60204-1, table 6 method B2
*
for
axis / for spindle
10/25 25/50
Max. allowable cross-section (mm²)
of flexible cable connector
35 35
Rated output frequency for A19/X11 0-550 Hz
**
Current bandwidth 800 Hz
Speed bandwidth
100 Hz · depends on the motor/drive set ·
*
The recommended cross-section depends on the rated operating power of the connected motor.
**
Equal to or higher than 550 Hz, only for QC-DR-...-
MDU