4.
F. H 4 / 3
. Outside appearance.
T1
U1
Floor fixture holes inside
the electrical cabinet
Chassis support.
Can turn 180 degrees after
loosening the four M3x8 screws
Metal flanges
for connecting
the power cable shields to the
chassis support
cable feedthrough
Connection terminals:
M8 connection screw to the
protective earth
Tightening torque: 8 N·m
3 cable feedthroughs,
45 mm
Fans
T1-T2-T3
Mains input phases to the CHOKE
U1-V1-W1
CHOKE output phases to the power supply
6x flip
covers
Dowel pin M10
Tightening torque: 10
20 N·m
4x eyebolts for
handling the unit
Characteristics plate
Eyebolts for
handling the unit
serial number
GND/24VDC.
+24 V DC input from an outside
auxiliary power supply
PTC thermistor.
N.A.
Range Ta: 70 °C ... 155 °C
PTC thermistor output to
the PLC input
Cable feedthrough for the +24 V DC
cables and the PTC thermistor
Chassis support.
Shield-to-chassis connection for the single-
pole power cables of the output phases
T2 T3