Installation
INSTALLATION
Electrical connections
8.
Ref.2003
· 271 ·
QC-PDS
HARDWARE
How to install ONE external braking resistor with internal
thermostat and with no fan
WARNING. On top of the ER+TH modules, the air temperature can reach
values over 120°C/248°F. Therefore, the resistor should be mounted away
from the rest of the modules or even outside the electrical cabinet, always
vertically and away from cables and other temperature sensitive material.
F. H8/26
QC-PS-
. The connection of ONE external braking resistor
with internal
thermostat and with no fan.
INTERNAL
THERMOSTAT
Tk
Tk
PLC INPUT
+ 24 V DC
160°C
RR
Braking resistor connection terminals
Tk
connection terminals of
the internal thermostat
Always install it vertically
R
R
Diagram
Connect either one of the two pins of the
thermostat to + 24 V DC of the external
power supply of the electrical cabinet and
the other one to a PLC input.
Important. Remember to manage the
chosen PLC input in the PLC program to
generate an error when exceeding the
limit temperature (160 °C) detected by
the sensor and to open the contact.
Connect the R terminals of the external braking resistor to the X15
connector on the QC-PS-
non-regenerative power supplies.
X15
R