Follow these guidelines when configuring the green box for calibration:
a. Ensure that area within the green calibration box contains only the floor, no walls or other
objects, and minimal or no pink shaded (undefined) areas.
b. If the box contains only floor and minimal pink shaded areas, continue to step 4.
c. If the box includes displays, walls, other objects, or pink shaded areas, click it and drag to
a different section of the image. If needed, you can click on the corners of the calibration
box and resize it, or click in the middle of the box and move the entire box so that it only
covers the floor.
Note: For the most accurate calibration results, make the
green calibration box as large as possible while still
covering only the floor area.
6. Click Auto-Calibrate. After several seconds, the sensor automatically calculates the height (cm),
and X and Y rotation.
7. Look at the height and rotation numbers to ensure that they are reasonable using the following
guidelines:
n Calculated height should be within 20% of visual height estimate.
n X and Y rotation should be within 10 degrees of visual angle estimate.